Altronix Strikeit1 Panic Device Controller / Power Supply/Charger

$ 105.59

Availability: 100 in stock
  • MPN: Does Not Apply
  • All returns accepted: ReturnsNotAccepted
  • Condition: New – Open box
  • Brand: Altronix
  • Model: Altronix Strikeit 1
  • Country/Region of Manufacture: United States

    Description

    Input
    Input 115VAC 60Hz, 6.3A.
    Two (2) NO trigger inputs.
    Input fuse rating: 6.3A.
    Outputs
    Power options:
    Two (2) 20VDC to 26.4VDC individually controlled lock outputs for applications with battery back-up. 24VDC for applications without battery back-up (US applications only). Current rating 15A for 300ms, 0.75A continuous supply current.
    5V holding voltage with 20VDC to 26.4VDC initial 100ms pulse. Maximum total 5V holding current of both outputs is 0.74A.
    One (1) 20VDC to 26.4VDC for applications with battery back-up, 24VDC for applications in US not requiring battery back-up. Auxiliary output rated @ 0.75 A continuous supply current (Not affected by FACP trigger).
    One (1) 12VDC filtered regulated auxiliary output rated @ 0.75A in alarm, 0.5A stand-by current (Not affected by FACP trigger).
    Two (2) follower form "C" relay outputs rated @ 0.6A/28VDC. Relays energize while input is closed.
    Two (2) delayed follower Normally Open relay outputs rated @ 0.6A/28VDC. Delay time is selectable 0.5 seconds or 1 second. Energized duration is 1 second.
    Trouble relay output indicating low DC output voltage.
    Battery Backup
    Battery leads included.
    Battery fuse rating: 25A/32V.
    Built-in charger for sealed lead acid or gel type batteries.
    Automatic switch over to stand-by battery when AC fails.
    When 7AH batteries are used, battery capacity for emergency stand-by is 30 minutes.
    Visual Indicators
    Green AC Power LED indicates 115VAC present.
    Green trigger input LEDs indicate panic device status/trouble (activated, short or open circuit).
    Red Fire Alarm Interface (FAI) LED indicates FACP disconnect is activated.
    Red Battery LED indicates low battery during AC failure and manual test.
    Green AC LED indicates loss of AC trouble (not active during manual test sequence).
    Fire Alarm Disconnect
    Normally Closed FACP trigger input.
    Programmable Fire Alarm Disconnect options:
    Removes power to outputs and disables delayed follower relays.
    Connects power to lock outputs and enables delayed follower relays.
    Additional Features
    Manual testing to allow to tests battery conditions.
    Adjustable panic release from 1 sec. to 30 secs.
    Note: Follower and Delay relay turns off when the potentiometer selected time elapses after release of the input trigger.
    Cam lock included.
    Temperature
    Operating 0° C to 49° C (32° F to 120° F).
    Storage - 20° C to 70ºC ( - 4° F to 158° F).
    Relative Humidity 85% +/- 5%.
    BTU/Hr (approx.): 36 BTU/Hr.
    System AC input VA requirement: 724.5VA.